Wednesday, 1 March 2017

VMUX-FRONT PANEL OF 2 MB ETHERNET CARD (TME CARD)



TME CARD   

            (i)         Front Panel

                        The front panel of 2MB Card is shown in figure below:
 
                       



The following table describes the front panel:

Item
LED
Status
LED Function
HEALTH
Blinking (Green/Red)
Red    ON
Card is working OK.

Card hardware has gone faulty.
P1 LCL
ON
Fast Blinking
Fast Blinking
Fast Blinking
Slow Blinking
Slow Blinking
PCM1 Loss of Signal
PCM1 Frame Sync. Loss
PCM1 Multiframe Sync. Loss
PCM1 CRC Frame Sync. Loss
PCM1 error rate > E103
PCM1 error rate > E106
P2 LCL
ON
Fast Blinking
Fast Blinking
Fast Blinking
Slow Blinking
Slow Blinking
PCM2 Loss of Signal
PCM2 Frame Sync. Loss
PCM2 Multiframe Sync. Loss
PCM2 CRC Frame Sync. Loss
PCM2 error rate > E103
PCM2 error rate > E106
P1 RMT
ON
Slow Blinking
Slow Blinking
Slow Blinking
PCM1 Receive AIS (All 1s)
PCM1 Receive Remote FSL
PCM1 Receive Remote MFSL
PCM1 Receive AIS in TS16
P2 RMT
ON
Slow Blinking
Slow Blinking
Slow Blinking
PCM2 Receive AIS (All 1s)
PCM2 Receive Remote FSL
PCM2 Receive Remote MFSL
PCM2 Receive AIS in TS16
CLOCK
Blinking
ON
Slips
Selected Clock Fail
TEST
ON
Card in diagnostics or Loop back Mode
TD NMS
Blinking
NMS Polls Transmitted
RD NMS
Blinking
NMS Polls Received
NMS Ethernet Connector
RJ-45 Connector for connection to NMS on LAN.
NMT
Connector
DB9 female, for connection to NMT. Connector pin allocation is described in this section later. This port is configured as DCE.
NMS RS-232 Connector
DB9 female, for connection to PC-Based NMS, Connector Pin allocation is described in this section later.  This port is configured as DCE.


Installation

·         Switch off the Power Supply, if ON.
·         Set the headers for 75 Ω or 120 Ω terminations as per the installation plan.
·         Insert 2MB Card in Slot No. 3 & lock it with the help of ejectors.
·         If PDP switch for this system is ON, then immediately Major Alarm will come ON and buzzer will sound.

·         Press ACO switch to cut Audio Alarm. ACO indicator should glow in this case.

If no audio alarm is generated check ON/OFF switch on PDP & wiring Alarm Extension Connector.

No comments: