POWER SUPPLY CARD
(i) Front
Panel
The
front panel of VMUX PSU Card is shown in figure below:
Installation
§ Set the ON/OFF Switch on the card to OFF position.
§ Insert the card in slot no. 1 or 2 & lock it in position in the
enclosure with the help of ejectors.
Make sure that ON/OFF switch on the Power Supply Card is in OFF position, before inserting/removing the card in slot. Also make sure that power switch on the PDP for the corresponding system is set to off for removing/inserting the power supply card. Inserting/removing the card in ON condition may damage the power supply connectors
The following table describes the front panel:
ITEM
|
DESCRIPTION
|
ON/OFF SWITCH
|
Turns the power ON/OFF. UP Position OFF, Down position ON.
|
Power
|
Green LED glows when –48V input is present.
|
Output Fail LED
|
Red LED lights when any of the output voltages i.e. +5V, +12V or
–12V fail.
|
Monitoring points
|
Monitoring points for input -48V, -48V return, +5V, Ground, +12V
& -12V
Warning
The monitoring points are unprotected & should be carefully
monitored.
|