Thursday, 2 March 2017

VMUX-FRONT PANEL OF FRACTIONAL E1 BRANCHING CARD



E1 BRANCHING MODULE CARD           

                 Front Panel
                        The front panel of E1 Branching module card is shown in figure below:


 



                       The following table describes the front panel:

ITEM
LED
Status
LED Function
HEALTH
Green ON
Blinking
Card is configured.
Card is deconfigured.
P1 LCL
ON
Fast Blinking
Fast Blinking
Fast Blinking
Slow Blinking
Slow Blinking
PCM1 Loss of Signal
PCM1 Frame Sync. Loss
PCM1 Multiframe Sync. Loss
PCM1 CRC Frame Sync. Loss
PCM1 error rate > E103
PCM1 error rate > E106
P2 LCL
ON
Fast Blinking
Fast Blinking
Fast Blinking
Slow Blinking
Slow Blinking
PCM2 Loss of Signal
PCM2 Frame Sync. Loss
PCM2 Multiframe Sync. Loss
PCM2 CRC Frame Sync. Loss
PCM2 error rate > E103
PCM2 error rate > E106
P1 RMT
ON
Slow Blinking
Slow Blinking
Slow Blinking
PCM1 Receive AIS (All 1s)
PCM1 Receive Remote FSL
PCM1 Receive Remote MFSL
PCM1 Receive AIS in TS16
P2 RMT
ON
Slow Blinking
Slow Blinking
Slow Blinking
PCM2 Receive AIS (All 1s)
PCM2 Receive Remote FSL
PCM2 Receive Remote MFSL
PCM2 Receive AIS in TS16
CLOCK
Blinking
Slips
TEST
ON
Card in diagnostics or Loop back Mode
TD NMS
Blinking
NMS Polls Transmitted
RD NMS
Blinking
NMS Polls Received



Installation

·         Set the headers for 75 Ω or 120 Ω terminations as per the installation plan.
·         Insert E1 Branching Module card in desired slot & lock it with the help of ejectors.
·         Configure the card and streams using either NMS or Local Port, if already not configured.

                 Route the desired port or streams as require

No comments: